Carlin Combustion
 
The 601GAS burner converts from propane to natural gas with just an orifice change - no conversion kit needed. Fires negative or positive chambers from 700,000 to 1,500,000 Btuh input. Dependable direct-spark ignition of main flame for quick clean light offs. Time-tested solid state ignition and state-of-the-art microprocessor primary control technology. Diagnostic LED lights annunciate operating mode: Self-check, Flame-on, Recycle, Lockout and Latch-up. Factory-packaged with combustion control and gas train (assembed, shipped loose; also available as knockdown). Shipped completely pre-wired for easy installation and start-up (knockdown version also available). High-efficiency, compact flame pattern design ensures clean, quiet operation. Does not require a refractory liner - fires with or without a combustion chamber. Swing-away housing design.
     
Input
 

700,000 to 1,500,000 Btuh

 
Fuels
  Natural Gas or Propane Gas
  Maximum Supply Pressure: 14 inches w.c.
Minimum Supply Pressure: 5.0 inches w.c.
Manifold Pressure: 3.5 inches w.c.
     
Control
 

Carlin 60200FR Microprocessor Control
4 sec. Trial for Ignition (TFI)
1.3 Sec. FFRT

Pre-purge and post-purge
Serviceman Reset Protection
Latch-up after three consecutive lockouts
Interrupted Duty Ignition

     
Electrical
  Power: 120 vac/60Hz/1-Phase
    Current: Approximately less than 10 amps
  Limit Circuit Input: 120 vac/60 Hz
 

Motor: 1/2 HP, 3450 RPM, 60 Hz, 8.4 amps

  Fuel Valve Power: 120 vac/60 Hz
 
Ignition
 

Carlin Model 41000 solid state electronic ignition

  Ignition Voltage: 14,000 volts
     
Orifice Selection
 
Contact Carlin
 
Agencies
  UL Listed: US