Carlin Combustion
 
    14,000 volt or 20,000 volt output for smooth gas ignition
    Solid state technology yields high performance, long life and durability
    Constant-duty rated
    Mounts on standard 4x4 j-box
    Primary power wires can be routed through bottom or side of housing
    Epoxy sealant provides water resistance and heat dissipation
    Consistent voltage output across a wide range of imput voltages
    Low current draw saves electrcity
    Easy testing - 42000 and 42700 ignitors' spark can jump 1/2" gap
     
Model 42000
   
Power Input
  120 vac, 60 Hz, 40 VA
Ignitor Output
  14 KV, 35 mA RMS
#16 AWG Style 3239, 150°C, 25 KVDC; exit bottom or side
Secondary Grounding
  Midpoint
Operating Temperature Limits
 

+ 32°F to + 140°F

Storage Temperature Limits
  -40°F to +185°F
Agencies
  UL Recognized (US), CSA Certified (Canada)
     
Model 42700
   
Power Input
  208-240 vac, 50/60 Hz, 60 VA
Ignitor Output
  14 KV, 35 mA RMS
Secondary Grounding
  Midpoint
Operating Temperature Limits
 

+ 32°F to + 140°F

Storage Temperature Limits
  -40°F to +185°F
Agencies
  NA
     
Model 42900
   
Power Input
  12 VDC, 50 VA
Ignitor Output
  20 KV, 28 mA RMS
Secondary Grounding
  Midpoint
Operating Temperature Limits
 

+ 32°F to + 140°F

Storage Temperature Limits
  -40°F to +185°F
Agencies
  NA