| The
201GAS burner converts from propane to natural gas with
just an orifice change - no conversion kit needed. Factory
packed with combustion control and gas fuel train. Does
not require a refractory liner - fires with or without a
combustion chamber. Proven in extensive boiler and furnace
testing, these burners will meet your needs for residential
gas burning applications. |
| |
|
|
|
Input
|
|
150,000
to 399,000 Btuh |
|
|
|
|
|
Fuels
|
|
Natural Gas or Propane Gas |
|
|
|
Maximum
Supply Pressure: 14 inches w.c. |
|
|
|
Minimum
Supply Pressure: 5.0 inches w.c. |
|
|
|
Manifold
Pressure: 3.5 inches w.c. |
| |
|
|
|
Control
|
|
Carlin
60200FR Microprocessor Control
4 sec. Trial for Ignition (TFI)
1.3 Sec. FFRT
Pre-purge
and post-purge
Serviceman Reset Protection
Latch-up after three consecutive lockouts
Interrupted Duty Ignition
Recyle on Flame Failure
|
| |
|
|
|
Electrical
|
|
Power:
120 vac/60Hz/1-Phase |
| |
|
Current:
Approximately 2.5 or 4.4 amps |
|
|
|
Limit
Circuit Input: 120 vac/60 Hz |
|
|
|
Motor:
1/6 or 1/4 HP, 3450 RPM, 60 Hz
|
| |
|
Motor
Frame: 48 Frame, "N" Flange |
|
|
|
Fuel Valve Power: 120 vac/60 Hz |
|
|
|
|
|
Ignition
|
|
Carlin
Model 41800 solid state electronic ignition
|
|
|
|
Ignition
Voltage: 9,000 volts |
| |
|
|
|
Orifice
Selection
|
|
|
|
|
|
|
|
Agencies
|
|
UL
Listed: US & Canada - US per ANSI Z21.17, Canada per
CSA 2.7 |
|
|
|
|